Neumovent (Dedicated Neonatal & Infant Ventilator.)
raphNet neo is a dedicated neonatal and infant ventilator from SCHILLER, designed for both invasive and non‑invasive respiratory support. It features a 12.1″ TFT‑LED touchscreen display, a proximal flow sensor for precise flow/volume monitoring (down to 2 ml tidal volume), automatic leak compensation, and advanced neonatal ventilation modes including TCPL, SIMV, PRVC, N‑CPAP and HFNC
Key Features
- Premium Quality Equipment
- Free Installation Support
- Manufacturer Warranty
- 24/7 Technical Support
Product Description
1. Intended Use & General Info
-Dedicated neonatal & infant ventilator
-Supports premature and neonatal/pediatric patients
-Provides invasive and non‑invasive ventilatory support
-Suitable for short-term and long-term ventilation
-Can be used for spontaneously breathing or fully ventilator‑dependent patients
2. Interface & Sensor / Monitoring
-12.1″ TFT‑LED colour touchscreen display for real-time waveforms & loops
-Proximal flow sensor at Y-piece for precise flow and volume monitoring
-Independent of circuit and humidifier compliance
-Supports tidal volumes as low as 2 ml (Volume Control mode)
3. Ventilation Modes & Therapies
-Time-Cycled Pressure-Limited (TCPL)
-SIMV (TCPL) + PSV
-N-CPAP (nasal continuous positive airway pressure), including Non-Invasive Ventilation (NIV)
-SIMV (PRVC) + PSV (volume-guaranteed / pressure-regulated volume control)
-Volume Support Ventilation (VSV)
-High Flow Oxygen Therapy (HFOT / HFNC) support
4. Advanced Features & Compensation / Safety / Monitoring
-Automatic leakage compensation
-Trigger sensitivity optimization (as low as 0.2 ml)
-Selectable apnea backup ventilation (volume or pressure type)
-Altitude and circuit compliance compensation
-Endotracheal tube resistance compensation (10%–100% for ET diameters Ø 2.5–6 mm)
-Advanced lung mechanics monitoring: Auto-PEEP, trapped volume, compliance & resistance, expiratory time constant, oxygen index (PaFi), P/V inflection points
5. Classification, Safety & Regulatory Standards
-Risk class IIb (EU) / Class III (MERCOSUR)
-Electrical insulation class I Type B
-IP21 protection
-Designed for continuous ICU operation
6. Physical & Operational Data
-Gas supply: medical-grade air and oxygen, supply pressure 280–600 kPa
-Delivered peak flow (neonatal mode): 0.2–40 L/min
-Continuous flow range (NEO-INF): 2–40 L/min
-Maximum limited pressure (relief valve): 120 cmH₂O
Technical Specifications
| Advanced Lung Mechanics Monitoring: | Auto‑PEEP, trapped volume, expiratory time constant (TCexp), compliance & resistance, oxygen index (PaFi), C20/C ratio, RVR monitoring |
| Advanced Modes: | SIMV (PRVC) + PSV, Volume Support Ventilation (VSV), Pressure Control and Volume Guaranteed with PRVC |
| Apnea Backup: | Selectable backup ventilation (Volume or Pressure type) |
| Circuit Independence: | Independent of circuit and humidifier compliance |
| Display: | 12.1″ TFT‑LED colour touchscreen for simultaneous waveform & loop visualization |
| ET Tube Compensation: | Endotracheal tube resistance compensation, 10%–100% for ET tube diameters Ø 2.5–6 mm |
| Environmental Compensation: | Altitude and circuit compliance compensation with leak correction in all modes |
| Flow Sensor: | Proximal flow sensor at Y-piece for precise flow/volume monitoring and fast trigger response |
| High Flow Therapy: | Supports HFOT / HFNC for non-invasive oxygenation/ventilation |
| Leak Compensation: | Automatic leakage compensation in all modes |
| Neonatal Ventilation Modes: | TCPL, SIMV (TCPL) + PSV, N-CPAP, Non-Invasive Ventilation (NIV) |
| Tidal Volume Range: | Minimum 2 ml in Volume Control (VC) mode |
| Trigger Sensitivity: | Continuously optimized trigger sensitivity from 0.2 ml with automatic termination criteria |
Download Documents
No documents available for download.